On a hot Austin summer day, shade temperatures can reach 104 degrees. Visitors queue outside, and as the line moves, they will eventually reach the Rotunda — the rehabilitated Bathhouse's new, air-conditioned entrance.

The architects' own construction documents suggest that keeping that queue orderly, and that air conditioning intact, may be harder than it sounds.

What the Plans Say

Sheet T1.02 of the 100% Construction Documents (Limbacher & Godfrey Architects, dated April 26, 2023) contains the project's Occupant Loads table — the code-required calculation of how many people each room is allowed to hold. For Room 4, the Rotunda, using the standard assembly-space factor of one person per 30 square feet, the table calculates an occupant load of 13 people for the Rotunda's 381 square feet. The adjoining Transaction and Passage areas are each calculated separately, at 1 person apiece. The Exhibits area has an occupant load of 25 people. Several of these people need to be CoA staff.

Occupant Loads table, Sheet T1.02
Occupant Loads table, Sheet T1.02, Zilker Metro Park Barton Springs Bathhouse Rehabilitation, April 26, 2023.

It is my understanding that the entire Rotunda is conditioned space with inoperable windows. In other words, there's no cracking a window for airflow — the Rotunda depends entirely on mechanical air conditioning, and its only connections to the outside air are its doors.

The Operational Question

That leaves the building's daily operation to reconcile a 13-person occupancy limit inside the Rotunda and 25-person occupancy of the Exhibits with a queue of visitors outside in well over 100-degree heat, every one of them eager to step into the air conditioning.

Questions for a journalist:

  • How will the Rotunda's 13-person occupancy limit be maintained when visitors are eager to step inside to feel the air conditioning? Similarly for the Exhibit's 25-person occupancy limit?
  • If the entry door is not closed between each visitor — and is instead propped open — how does the operational plan account for the resulting loss of air conditioning?
  • Who is responsible for monitoring the number of visitors inside the Rotunda to ensure compliance with the stated occupancy limit?

Sources

Sheet T1.02, “Design Data” / Occupant Loads table, from the 100% Construction Design Intent Document set for the Zilker Metro Park Barton Springs Bathhouse Rehabilitation (Limbacher & Godfrey Architects, April 26, 2023; City contract CSP 6100 CLMB341 / CIP 6066.035). Source: CSP_6100_CLMB341_PLANS_v1.pdf; full sheet also available as “BSBH Cover page 2 Occupant loads.pdf”.